Biosafety Cabinet Class I / Biological Safety Cabinet Solutions / Biosafety Cabinet China

Biosafety Cabinet Class I / Biological Safety Cabinet Solutions / Biosafety Cabinet China

    • Biosafety Cabinet Class I / Biological Safety Cabinet Solutions / Biosafety Cabinet China
    • Biosafety Cabinet Class I / Biological Safety Cabinet Solutions / Biosafety Cabinet China
    • Biosafety Cabinet Class I / Biological Safety Cabinet Solutions / Biosafety Cabinet China
    • Biosafety Cabinet Class I / Biological Safety Cabinet Solutions / Biosafety Cabinet China
  • Biosafety Cabinet Class I / Biological Safety Cabinet Solutions / Biosafety Cabinet China

    Szczegóły Produktu:

    Miejsce pochodzenia: Guangdong Chiny (kontynentalne)
    Nazwa handlowa: SUCLAB
    Orzecznictwo: SEFA SGS ISO9001 ISO14001 OHSAS
    Numer modelu: HUAZHIJUN-776

    Zapłata:

    Minimalne zamówienie: 1 sztuk
    Szczegóły pakowania: Normalne kartony do eksportu drewna
    Czas dostawy: 15 dni po otrzymaniu depozytu
    Zasady płatności: EXW, T / T
    Możliwość Supply: 10000 sztuk każdego miesiąca
    Skontaktuj się teraz
    Szczegółowy opis produktu

    Biosafety Cabinet Class I / Biological Safety Cabinet Solutions / Biosafety Cabinet China

     

    Features of Biosafety Cabinet Class I:

    1.Front window: when using optical perspective is clear, clean and disinfect does not negatively 

    impact burst-proof tempered glass, tempered glass production, glass thickness ≥ 5 mm.

     

    2.Cabinet: four two-tier structure, all Studio and the collecting tank to use imports 304 stainless 

    steel materials.

     

    3.Operations on three sides and side wall panels unibody structure, leave some space

    at the bottom,easy to clean, to avoid cross infection.

     

    4.Blower/motor maintenance and disassembly, replacement HEPA filters are available from all 

    safety cabinets.

     

    5.Containment of the Cabinet: the cabinets pressurized to 500Pa, keep the air pressure 

    is not lower than 450Pa after 30min.

     

    6.Cabinet stability: a countertop Center load 23kg unload, countertop must not bend downward.

     

    7.Alarm system: safety Cabinet front window opening height exceeds a set level, decreased 

    safety Cabinet flow velocity and flow fluctuation of air flow velocity in excess of their nominal 

    value of 20%, the interlocking system startup, sound, light, sound and alarm.

     

    8.HEPA filter integrity: scan filter at any point of the leak rate of less than 0.01%.

     

    9.Cannot scan filters detect leak rate of less than 0.005% personal protection: percussive 

    sampler number ≤ 10CFU/.

     

    10.Slit type sampler number ≤ 5CFU/product protection: colony count ≤ 5CFU/cross 

    infection: colony count ≤ 2CFU/.

     

    Technical Parameters of Biosafety Cabinet Class I:

    Product name

    Biosafety Cabinet Class I

    Index/type technical parameter

    HZJBSC-1100-LⅡA2

    HZJBSC-1360-LⅡA2

    HZJBSC-1800IIA2

    Exhaust volume

    30% exhaust

    HEPA filter leakage ratio

    ≤0.005%

    Wind speed

    Inflows flow average wind speed: >0.5M/s

    Downdrafts in average wind speed: 0.25-0.5 m/s

    Noise

     ≤62dB(A)

    Semi-peak

    ≤3μm(rms)

    Illumination

    ≥700LX

    Display

    LCD + remote control

    Power supply

    Single AC 220V/50Hz

    Normal power consumption

    0.85kw

    Max power consumption

    1.85kw (including two spare socket 1000W)

    Weight

    305kg

    320kg

    326kg

    Workspace dimensions

    1220x600x680mm

    1360x600x680mm

    1800x600x680mm

    Device overall dimension

    1382x790x2150mm

    1525x790x2150mm

    1940x790x2150mm

    Air filter specifications 

    and quantity

    1215x500x50mmx①

    1355x500x50mmx①

    1795x500x50mmx①

    Exhaust air filter specifications 

    and quantity

    600x440x90mmx①

    740x400x90mmx①

    865x440x90mmx①

    Fluorescent lights/UV lamps 

    specifications and quantity

    30w×②/30w×①

    40w×②/40w×①

    40w×②/40w×①

    The number of applicable

    Single double single

    Double single

    More than 

    single-sided

     

    Contact Informations:

    Contact person:Mr.Johnny

    E-mail:johnnyli@chinafumehood.com

    Skype:johnny19900908

    Whatsapp:8613433636213

    Web:http://www.chinafumehood.com

     

     

     

     

    Szczegóły kontaktu
    Huazhijun Laboratory Equipment Co., Ltd

    Osoba kontaktowa: Jack

    Tel: +8613433636213

    Wyślij zapytanie bezpośrednio do nas (0 / 3000)

    Inne produkty